Rexroth A4VG90 A4VG125 A4VG180 A4VG250 Hydraulic Pump
Rexroth A4VG90 A4VG125 A4VG180 A4VG250 Hydraulic Pump
Rexroth Hydraulic pump A4VG90 from china for use in Concrete mixer
Brueninghaus Hydromatik Rexroth A4VG pump
Hydraulic variable displacement axial pump A4VG40, A4VG56, A4VG71, A4VG90, A4VG125, A4VG180, A4VG250
Series 32
Nominal pressure 400 bar
Peak pressure 450
Control device: NV, HD3, HW, DG, DA1, DA2, EP3, EP4, EZ1, EZ2
The A4VG axial piston variable pump in swash plate design for hydrostatic closed circuit transmissions
- Flow is proportional to drive speed and displacement and is infinitely variable
- Output flow increases with the swivel angle of the swash plate from 0 to its maximum value
- Flow direction changes smoothly when the swash plate is moved through the neutral position
- A wide range of highly adaptable control devices is available for different control and regulating functions
- The pump is equipped with two pressure-relief valves on the high pressure ports to protect the hydrostatic transmission (pump and motor) from overload
- The high-pressure relief valves also function as boost valves
- The integrated boost pump acts as a feed and control oil pump
- The maximum boost pressure is limited by a built-in boost pressure relief valve
- The integral pressure cut-off is standard
Technical Data
Table of values (theoretical values, without efficiency and tolerances; values rounded)
|
Size
|
A4VG40
|
A4VG56
|
A4VG71
|
A4VG90
|
A4VG125
|
A4VG180
|
A4VG250
|
Displacement
variable pump
|
Vg max
|
cm3
|
40
|
56
|
71
|
90
|
125
|
180
|
250
|
|
boost pump (20 bar)
|
Vg Sp
|
cm3
|
8.6
|
11.6
|
19.6
|
19.6
|
28.3
|
39.8
|
52.5
|
Speed
maximum Vg max
|
conti.
|
rpm
|
4000
|
3600
|
3300
|
3050
|
2850
|
2500
|
2400
|
|
limited maximum
|
limited
|
rpm
|
4200
|
3900
|
3600
|
3300
|
3250
|
2900
|
2600
|
|
intermittent max.
|
Min.
|
rpm
|
5000
|
4500
|
4100
|
3800
|
3450
|
3000
|
2700
|
|
nmin
|
rpm
|
500
|
500
|
500
|
500
|
500
|
500
|
500
|
Flow
continuous and Vg max
|
l/min
|
160
|
202
|
234
|
275
|
356
|
450
|
600
|
Power
continuous Vg max
|
400 bar
|
kW
|
107
|
134
|
156
|
183
|
237
|
300
|
400
|
Torque
at Vg max
|
400 bar
|
Nm
|
255
|
356
|
451
|
572
|
795
|
1144
|
1590
|
|
100 bar
|
Nm
|
63.5
|
89
|
112.8
|
143
|
198.8
|
286
|
398
|
|
Moment of inertia
|
JGR
|
kgm2
|
0.0038
|
0.0066
|
0.0097
|
0.0149
|
0.0232
|
0.0444
|
0.0983
|
|
Angular acceleration
|
α
|
rad/s2
|
30000
|
24000
|
21000
|
18000
|
14000
|
11000
|
6700
|
|
Filling capacity
|
V
|
L
|
1.1
|
1.5
|
1.3
|
1.5
|
2.1
|
3.1
|
6.3
|
|
Weight approx.
|
m
|
kg
|
31
|
38
|
50
|
60
|
80
|
101
|
156
|